Free shipping
Australia wide delivery
Low prices
Müller VS 1x.18 - Analogue Din Mount 24hr Timer

Müller VS 1x.18 - Analogue Din Mount 24hr Timer

Theben SYN 160a Din Mounted 24hr Analogue Timer

Theben SYN 160a Din Mounted 24hr Analogue Timer

Müller VS 2x.18 - Analogue Din Mount 24hr Timer

Overview

  • Daily program
  • Slim format 35 mm
  • Captive setting keys
  • Manual override switch Permanent ON / Permanent OFF / AUTO

Intended use

  • The device fits for the particular use of the following tasks: Illumination of private and industrial areas, street and shop-window lightening, regulation of air conditioning, flushing, motors, pumps, plants and machinery as well as to simulate presence etc.
  • Operate the device in a dry room only!
  • The installation must be in accordance with the instruction manual.
  • The device is not qualified for security relevant tasks such as emergency doors, fire protection equipment.

Supply voltage versions

  • 230 V, 50-60 Hz
  • 115 V, 50-60 Hz
  • 12-24 V DC & 24-48 V, 50-60 Hz

Technical data

Supply voltage 230 V, 50-60 Hz
other voltages on request
Power consumption (real power) 0,4 W
Switch (potential-free) Change-over, contact gap < 3mm (µ)
Manual override switch Permanent ON / Permanent OFF / AUTO
Contact material AgSnO2
Switching capacity
resistive load:
inductive load:

16 A / 250 V~ at cosφ=1
2,5 A / 250 V~ at cosφ=0,6
Min. switching power 1.000 mW (10 V / 10 mA)
Filament Lamp, Halogen Lamp 2.000 W
Fluorescent Lamp uncopensated 1.000 W
Fluoresent Lamp series compensated 750 W
LED (230 V~) / CFL 200 W
Minimum switching interval 30 Min.
Time base Quartz
Accuracy (at 23°C) ≤±1 Sec./day
Power back-up (at 20°C) approx. 100 h.
Permitted ambient temperature –5°…+50°C
Housing self-extinguishing thermoplastic
Dimensions 45 x 35 x 58 mm
Mounting 35 mm DIN-Schiene
Type of connection Screw terminals
Type of protection IP 20 to DIN EN 60529
Class of protection II when installed according to regulations
Mode of operation
(DIN EN 60730-1)
(DIN EN 60730-2-7)
1 BSTU
Degree of contamination
(DIN EN 60730-1)
2
Rated surge voltage
(DIN EN 60730-1)
4 kV
SKU
AMPVS20.18

Overview

  • Daily program
  • Slim format 35 mm
  • Captive setting keys
  • Manual override switch Permanent ON / Permanent OFF / AUTO

Intended use

  • The device fits for the particular use of the following tasks: Illumination of private and industrial areas, street and shop-window lightening, regulation of air conditioning, flushing, motors, pumps, plants and machinery as well as to simulate presence etc.
  • Operate the device in a dry room only!
  • The installation must be in accordance with the instruction manual.
  • The device is not qualified for security relevant tasks such as emergency doors, fire protection equipment.

Supply voltage versions

  • 230 V, 50-60 Hz
  • 115 V, 50-60 Hz
  • 12-24 V DC & 24-48 V, 50-60 Hz

Technical data

Supply voltage 230 V, 50-60 Hz
other voltages on request
Power consumption (real power) 0,4 W
Switch (potential-free) Change-over, contact gap < 3mm (µ)
Manual override switch Permanent ON / Permanent OFF / AUTO
Contact material AgSnO2
Switching capacity
resistive load:
inductive load:

16 A / 250 V~ at cosφ=1
2,5 A / 250 V~ at cosφ=0,6
Min. switching power 1.000 mW (10 V / 10 mA)
Filament Lamp, Halogen Lamp 2.000 W
Fluorescent Lamp uncopensated 1.000 W
Fluoresent Lamp series compensated 750 W
LED (230 V~) / CFL 200 W
Minimum switching interval 30 Min.
Time base Quartz
Accuracy (at 23°C) ≤±1 Sec./day
Power back-up (at 20°C) approx. 100 h.
Permitted ambient temperature –5°…+50°C
Housing self-extinguishing thermoplastic
Dimensions 45 x 35 x 58 mm
Mounting 35 mm DIN-Schiene
Type of connection Screw terminals
Type of protection IP 20 to DIN EN 60529
Class of protection II when installed according to regulations
Mode of operation
(DIN EN 60730-1)
(DIN EN 60730-2-7)
1 BSTU
Degree of contamination
(DIN EN 60730-1)
2
Rated surge voltage
(DIN EN 60730-1)
4 kV
Write Your Own Review
You're reviewing:Müller VS 2x.18 - Analogue Din Mount 24hr Timer